Key result
Transcatheter ASD closure using the GORE CARDIOFORM ASD occluder achieved procedural success in 85% of patients, with no major adverse events or residual shunt at follow-up.
Why the study?
Does the GORE CARDIOFORM ASD occluder safely and effectively close atrial septal defects in children and adults?
Observational (n=26)
Yes
Does the GORE CARDIOFORM ASD occluder safely and effectively close atrial septal defects in children and adults?
The GORE CARDIOFORM ASD occluder appears safe and effective for transcatheter ASD closure, achieving high procedural success without residual shunting or major adverse events at short-term follow-up.
Answers are grounded in this paper and cite their sources.
Supports further evaluation of GORE CARDIOFORM ASD occluder; leaves open need for randomized trials before practice change.
OBJECTIVES: CARDIOFORM ASD Occluder (GCO). BACKGROUND: Transcatheter closure has become the treatment of choice for secundum ASD. A wide range of occluder devices are available, but concern has been raised about the risk of cardiac erosion associated with rigid devices and future access to the left atrium METHODS: Retrospective chart review of patients treated with the GCO at three Canadian centers. Primary outcomes were procedural success and residual shunting at follow-up, as well as 30-day major adverse events. Secondary outcomes included new onset atrial arrhythmias, wire frame fractures (WFF), and all cause mortality. Clinical, echocardiographic, procedural data, and follow-up outcome variables were collected in each participating hospital. RESULTS: Between February and December 2015, 26 patients (5 children and 21 adults) underwent transcatheter ASD closure with the GCO and were included in the study cohort. Procedural success was achieved in 22 of 26 patients (85%) and no major procedural complications were observed. Two patients (8%) presented new onset atrial tachyarrhythmia during early follow-up (0-30 days). Follow-up echocardiography (median of 119 days [IQR: 92-146]) demonstrated no residual shunt in all implanted patients. After a median clinical follow-up of 174 days (IQR: 135-239), one patient died of an unrelated cause, there were no documented major adverse cardiovascular events. Fluoroscopic imaging of the device was performed in 20 patients (91%), and WFF was noted in five cases. No clinical consequence or device dysfunction was observed in these patients. CONCLUSIONS: In this first-in-man multicenter study, the GCO was safe and effective for ASD closure, with no major adverse events or residual shunt at follow-up.
No takes yet. Share an insight, caveat, or question.
Hemptinne et al. (2017) conducted an observational in Secundum atrial septal defect (n=26). GORE CARDIOFORM ASD occluder (GCO) was evaluated on Procedural success, residual shunting at follow-up, and 30-day major adverse events. Transcatheter ASD closure using the GORE CARDIOFORM ASD occluder achieved procedural success in 85% of patients, with no major adverse events or residual shunt at follow-up.