Answers are grounded in this paper and cite their sources.
In order to master the position variation rule of radar false alarm signal under continuous wave (CW) electromagnetic interference and reveal the mechanism of CW on radar, taking a certain type of stepping frequency radar as the research object, theoretical analysis of the imaging mechanism of radar CW electromagnetic interference false alarm signals from the perspective of time-frequency decoupling and receiver signal processing. Secondly, electromagnetic interference injection method is used to test the single-frequency and dual-frequency electromagnetic interference effect of the tested equipment. The results show that under the single frequency CW electromagnetic interference, the sensitive bandwidth of false alarm signal is about ±75 MHz, and the position of false alarm signal irregularity changes. Under the in-band dual-frequency CW electromagnetic interference, the position of non-intermodulation false alarm signal is similar to that of single frequency. However, the distance difference of two non-intermodulation false alarm signals is regular. In addition, the positions of the second-order intermodulation false alarm signals of the tested radar are also regular, and its position changes with the change of the second-order intermodulation frequency difference.
No takes yet. Share an insight, caveat, or question.
Du et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: