Key result
Transthoracic Doppler sonography successfully measures spinal arterial flow, peaking at ~43 cm/sec at Th9.
Why the study?
There has been no study on the measurement of blood flow of the intercostal artery or lumbar artery using transthoracic Doppler sonography.
Can transthoracic Doppler sonography be used to measure blood flow in the intercostal and lumbar arteries of healthy subjects?
Observational (n=12)
Can transthoracic Doppler sonography be used to measure blood flow in the intercostal and lumbar arteries of healthy subjects?
Transthoracic Doppler sonography is a feasible, non-invasive method to evaluate intercostal and lumbar artery blood flow, potentially aiding in spinal cord circulation assessment during aortic aneurysm repair.
Transthoracic Doppler sonography may measure intercostal and lumbar artery flow in healthy subjects; leaves open its role in spinal cord assessment during aortic repair.
OBJECTIVE: There has been no study on the measurement of blood flow of the intercostal artery (ICA) or lumbar artery (LA) with the use of transthoracic Doppler sonography. Here, the method of the ICA depiction and flow measurement were described, and we suggested the clinical usage of this method. METHODS: Twelve healthy subjects were examined. The performance of transthoracic Doppler sonography was approached from the back on lateral decubitus position. The intercostal artery was depicted by two-dimension mode with color flow, and the inner diameter was measured. Peak systolic velocity (PSV), end-diastolic velocity (EDV), velocity-time integral (VTI), and heart rate (HR) were measured with pulsed Doppler, and the blood flow was calculated. RESULTS: Bilateral ICAs and LAs from Th4 to L4 were measurable with this method. The PSV of Lt Th9 was the fastest at 43.3 +/- 10.1 cm/sec and the PSV of the ICAs gradually decreased as distance from Th9 increased. As for the flow volume, the left Th11 was the greatest at 99.7 mL/min, and the flow volume of the ICA gradually decreased as distance from Th11 increased. The velocity and blood flow of right ICA tended to be lower than the left in the same spinal level. CONCLUSIONS: Evaluation technique of serial ICAs and LAs was shown. We think that it may be a clinically useful method in the study of spinal cord circulation in the repair of cases of descending thoracic or thoracoabdominal aortic aneurysm.
No takes yet. Share an insight, caveat, or question.
Koyanagi et al. (2009) conducted an observational in Healthy (n=12). Transthoracic Doppler sonography was evaluated on Measurement of blood flow (peak systolic velocity, end-diastolic velocity, velocity-time integral) of intercostal and lumbar arteries. Transthoracic Doppler sonography successfully measured blood flow in bilateral intercostal and lumbar arteries, with the highest peak systolic velocity observed at the left Th9 (43.3 +/- 10.1 cm/sec).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: