Failure or degradation effects lead to power losses in solar panels during their field operation and are identified commonly by electroluminescence (EL) imaging. Some failures like potential-induced degradation (PID) and light and enhanced temperature induced degradation (LeTID) require an identification of the EL pattern over the entire solar panel. As the manual process of analyzing patterns is prone to error, we seek for an automatic detection of these failure types. We predict automatically the failure types PID and LeTID by adopting the principal component analysis (PCA) method in combination with a k-nearest neighbor (kNN) classifier. We increase the explained variance of the PCA by 4 %abs using a Gaussian blurring preprocessing step and gain insights into the basic mechanism of the machine learning algorithm by analyzing schematic EL images. The kNN classifier predicts the failure classes in the same way as the expert. Finally, we work with a larger test dataset of 40 similar images to mimic a field-typical user case and meet again the expert classification.
No takes yet. Share an insight, caveat, or question.
Bordihn et al. (2022) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: