Key result
Mixing pressure, volume, and stroke volume achieves global identifiability in a six-chamber cardiovascular model.
Why the study?
The six-chamber cardiovascular system model and its derivatives are not identifiable from any output set when only a single type of information is used, limiting their diagnostic utility.
Demonstrates that the six-chamber cardiovascular system model is structurally globally identifiable from limited clinical measurements, supporting its potential use in diagnosis.
Answers are grounded in this paper and cite their sources.
May support model-based diagnostics from routine measurements; leaves open prospective clinical validation.
The six-chamber cardiovascular system model of Burkhoff and Tyberg has been used in several theoretical and experimental studies. However, this cardiovascular system model (and others derived from it) are not identifiable from any output set. In this work, two such cases of structural non-identifiability are first presented. These cases occur when the model output set only contains a single type of information (pressure or volume). A specific output set is thus chosen, mixing pressure and volume information and containing only a limited number of clinically available measurements. Then, by manipulating the model equations involving these outputs, it is demonstrated that the six-chamber cardiovascular system model is structurally globally identifiable. A further simplification is made, assuming known cardiac valve resistances. Because of the poor practical identifiability of these four parameters, this assumption is usual. Under this hypothesis, the six-chamber cardiovascular system model is structurally identifiable from an even smaller dataset. As a consequence, parameter values computed from limited but well-chosen datasets are theoretically unique. This means that the parameter identification procedure can safely be performed on the model from such a well-chosen dataset. Thus, the model may be considered suitable for use in diagnosis.
No takes yet. Share an insight, caveat, or question.
Pironet et al. (2016) studied Cardiovascular system modeling. Specific output set mixing pressure and volume information vs. Output sets containing only pressures or only volumes was evaluated on Structural global identifiability. The six-chamber cardiovascular system model is structurally globally identifiable when using a specific output set mixing pressure and volume information, including stroke volume.
Synapse has enriched 10 related papers. Consider them for comparative context: