Large recirculation cyclones with high concentrations of particulate solids have gained considerable importance in the field of circulating fluidized bed technology. To calculate a combustion process, the influence of the cyclone on the circulating quantity of solids and their grain size distribution must be known. Measurements in a 105‐MW‐plant in 1989 showed that the existing cyclone theory was not sufficient for this purpose. In a laboratory cyclone (900 mm in diameter), the separation and classification of solids in a gas flow was investigated. The cyclone was fed from a fluidized bed and operated with cold air and quartz of various grain size distributions. Based on this experimental device and the theory of momentum transfer between solids and gas flow, a new, more accurate method of calculating the separation efficiency was developed.
No takes yet. Share an insight, caveat, or question.
Trefz et al. (1993) studied this question.