Answers are grounded in this paper and cite their sources.
A simple needle-trap device (NTD) coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine trace levels of nitrobenzenes (NBs) in workplace air. The NTD with sorbent inside the needle was employed for the quantification of nitrobenzene, o-nitrotoluene, m-nitrotoluene, p-nitrotoluene, o-nitrochlorobenzene, m-nitrochlorobenzene, and p-nitrochlorobenzene. The optimum temperature and time for desorption of analytes were 270 °C and 4 min, and parameters such as sampling flow rate, breakthrough volume, and storage capability were also optimized. The limits of detection and quantification were in the ranges of 1.8 × 10−4–1.1 × 10−3 and 5.9 × 10−4–3.6 × 10−3 mg m−3, respectively. The developed protocol was successfully applied for the determination of NBs in vehicle repair plants where the highest detected concentration was 0.11 mg m−3. The established NTD-GC-MS generally applies to monitoring trace levels of NBs in the air.
No takes yet. Share an insight, caveat, or question.
Dong et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: