Key result
A closed-loop artificial pancreas control system increased the percentage of glucose concentration within the target range compared to open-loop control.
Why the study?
Does a closed-loop artificial pancreas control system reduce hypoglycemia and improve time in target glucose range in patients with type 1 diabetes?
Does a closed-loop artificial pancreas control system reduce hypoglycemia and improve time in target glucose range in patients with type 1 diabetes?
Answers are grounded in this paper and cite their sources.
An integrated multivariable artificial pancreas control system with a hypoglycemia early alarm effectively maintains glucose within target range and prevents hypoglycemia in type 1 diabetes.
The objective was to develop a closed-loop (CL) artificial pancreas (AP) control system that uses continuous measurements of glucose concentration and physiological variables, integrated with a hypoglycemia early alarm module to regulate glucose concentration and prevent hypoglycemia. Eleven open-loop (OL) and 9 CL experiments were performed. A multivariable adaptive artificial pancreas (MAAP) system was used for the first 6 CL experiments. An integrated multivariable adaptive artificial pancreas (IMAAP) system consisting of MAAP augmented with a hypoglycemia early alarm system was used during the last 3 CL experiments. Glucose values and physical activity information were measured and transferred to the controller every 10 minutes and insulin suggestions were entered to the pump manually. All experiments were designed to be close to real-life conditions. Severe hypoglycemic episodes were seen several times during the OL experiments. With the MAAP system, the occurrence of severe hypoglycemia was decreased significantly (P < .01). No hypoglycemia was seen with the IMAAP system. There was also a significant difference (P < .01) between OL and CL experiments with regard to percentage of glucose concentration (54% vs 58%) that remained within target range (70-180 mg/dl). Integration of an adaptive control and hypoglycemia early alarm system was able to keep glucose concentration values in target range in patients with type 1 diabetes. Postprandial hypoglycemia and exercise-induced hypoglycemia did not occur when this system was used. Physical activity information improved estimation of the blood glucose concentration and effectiveness of the control system.
No takes yet. Share an insight, caveat, or question.
Turksoy et al. (2014) studied Type 1 diabetes. Closed-loop artificial pancreas control system vs. Open-loop control was evaluated on Percentage of glucose concentration within target range (70-180 mg/dl) (p=<.01). A closed-loop artificial pancreas control system increased the percentage of glucose concentration within the target range compared to open-loop control.
Synapse has enriched 10 related papers. Consider them for comparative context: