Answers are grounded in this paper and cite their sources.
By means of cyclic voltammetry as a diagnostic technique, the present study tried to describe the behaviour of dopamine (DP) at the bare and catechol electrografted glassy carbon electrode (CA/GCE). The results indicated that the CA/GCE exhibits high electrocatalytic activity toward DP. The DP cycling of the CA/GCE in DP showed two linear calibration ranges between 5.0?100 and 100?750 ?M with a detection limit of 0.86 ?M. For 6 DP replicate measurements (50 ?M); the relative standard deviation (RSD) was 2.7 %. This method was successfully used for the determination of DP in serum samples.
No takes yet. Share an insight, caveat, or question.
Pourghobadi et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: