Answers are grounded in this paper and cite their sources.
In this paper, the effect of direct lightning strikes on the wind turbine is studied for the earth system with homogeneous soil and circular and cylindrical electrodes connected and without them. The location of wind turbines and the structure of their bodies have caused serious economic losses when lightning strikes the turbines. The design of wind turbine grounding system is very important for the safety of personnel and protection of electrical equipment. Simple soil has a relative electrical permeability coefficient of 10 and a conductivity coefficient of 0.1. The wind turbine ground system is considered with homogeneous soil and with 9 vertical electrodes and 5 horizontal electrodes connected in the form of circle and cylinder. The overall dimensions of the wind turbine include the blade length of 24 meters, nacelle length of 6 meters, width of 6 meters and height of 6 meters, and the tower of the wind turbine is made of a steel cone with a height of 44 meters. The simulation results in the full wave HFSS software for two cases with and without the electrode based on the distribution of the fields created on the components of the wind turbine resulting from the direct impact of lightning and the effect of overvoltage created at different frequencies were investigated and compared. Is. Based on this, it can be concluded that the arrangement of electrodes and ground resistance plays a very important role for the design of the wind turbine farm and its protection.
No takes yet. Share an insight, caveat, or question.
Hossein Malekpoor (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: