Answers are grounded in this paper and cite their sources.
A numerical analysis of a shear horizontal surface acoustic wave (SH-SAW) immunoassay biosensor has been investigated. A numerical calculation method proposed by Campbell and Jones has been generally used to calculate SAW propagation characteristics. In this paper, a numerical calculation method for SH-SAW propagation characteristics, which is a modified method of Campbell and Jones involving the effect of liquid viscosity is applied to quartz. In order to confirm the numerical analysis, 250 MHz SH-SAW delay-lines on quartz substrates are tested using glycerol mixtures of different concentrations of 0, 10, 20 and 30 wt%. In the experiments, the velocity and attenuation changes of the SH-SAWs are seen to increase as glycerol mixture concentrations are incrementally increased, as theoretically expected. Very good agreements between theoretical and experimental results are obtained.
No takes yet. Share an insight, caveat, or question.
Goto et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: