Key result
Novel hydrogel paving for coronary stents shows effective in situ delivery with complete physiological erosion.
Why the study?
An experimental protocol for in situ gel-paving of coronary stents using Pluronic F127/alginate blends was developed to enable pharmacological treatment of in-stent restenosis.
Does in situ gel-paving with Pluronic F127/alginate resist erosion in a simulated coronary artery model?
Does in situ gel-paving with Pluronic F127/alginate resist erosion in a simulated coronary artery model?
An experimental Pluronic F127/alginate gel blend for in situ coronary stent paving demonstrated appropriate erosion kinetics in an in vitro simulated artery model, suggesting potential as a local drug delivery system for in-stent restenosis.
Answers are grounded in this paper and cite their sources.
Premature for clinical stent use; leaves open feasibility as a local drug delivery platform pending in vivo studies.
In this work the development of an experimental protocol to perform the in situ gel-paving of coronary stent is presented. Biocompatible aqueous blends of Pluronic F127 and sodium alginates are used as potential drug dosage system for pharmacological in situ treatment of coronary in-stent restenosis. Pluronic F127/alginate aqueous blend has the unique characteristic to be liquid at room condition and to form gel at physiological temperature. The proposed protocol is based on the blend injection on stent wall previously implanted in a flexible silicon pipe mimicking the coronary artery. Injected blend is warmed up until human body temperature achieving a soft gel, then it is reticulated by copper bivalent ions to obtain an hard gel. To test the gel paving resistance to erosion phenomena when it is exposed to fluid flux (i.e. blood flux) a dedicated device, (the Simulated Artery Device, SAD), was built to simulate the human circulatory apparatus. The SAD is an hydraulic circuit in which a buffer solution (at pH 7.4) was fluxed by a peristaltic pump through the pipe hosting the covered stent. Erosion tests were performed monitoring, by gravimetric and spectrophotometric methods, the residual mass anchored to stent mesh after given times. The obtained results showed that the in situ gel-paving developed protocol was efficacious and reliable. The gel-paving was completely eroded in a time of the same order of magnitude of the physiological period required to restore the coronary lesion (subsequent to the atheroma removal) and of a pharmacological therapy to inhibit the in-stent-restenosis pathology.
No takes yet. Share an insight, caveat, or question.
Dalmoro et al. (2015) studied Coronary in-stent restenosis. In situ gel-paving of coronary stent using Pluronic F127 and sodium alginates was evaluated on Gel paving resistance to erosion phenomena (residual mass anchored to stent mesh). An experimental protocol for in situ gel-paving of coronary stents using Pluronic F127 and sodium alginates was efficacious, with the gel completely eroding in a physiologically relevant timeframe.
Synapse has enriched 10 related papers. Consider them for comparative context: