hydrodynamics, the apparatus must maintain overall physical uniformity and alignment throughout the test.Standard dissolution apparatus may be obtained from manufactures that produce the equipment according to the specification and tolerances outlined in General Test Chapter <711> Dissolution (2).For low concentrations of API, official compendial apparatus may be incapable of maintaining quantitative levels of analyte during the dissolution of oral dosage units containing microgram or nanogram levels.Dissolution of typical high-potency, low-dose compounds may require a reduction in vessel volume accompanied by an alteration in apparatus design due to limitations in detection and quantitation.If a reduction in volume is considered and the apparatus is modified, the operating conditions of the modified apparatus should maintain the same degree of precision and alignment required for any other compendial dissolution apparatus.Small-volume apparatus are desired not only for high-potency, low-dose formulations.Small-volume dissolution utilizing a mini paddle has been suggested as an alternative to standard paddle methods that require large volumes of biorelevant medium.This can be very expensive, and there may be limitations of large sample size or active drug availability in the early stages of drug development (3).In the current regulatory environment, our dissolution methods must be accurate, sensitive, and specific, and the reproducibility of the test method employed must be established, verified, and documented (4).Additionally, the method must maintain limits of detection and quantitation, range, and linearity and discriminate variation from batch to batch.Small-volume apparatus components should be precisely designed, rugged, and ABSTRACTThe concept of small-volume dissolution arises from the need to determine the dissolution rate from low-dose, generally high potency drugs or drugs with analytical techniques that are not very sensitive.Novel drug delivery products including subcutaneous implants, ocular systems, microspheres, nanospheres, and combination products such as drug-eluting stents (DES) have demanded more from traditional dissolution and drug-release apparatus.To maintain quantitative levels of analyte during the dissolution test, a reduction in vessel volume accompanied by an alteration of compendial dissolution apparatus may be required (1).The utilization of small-volume dissolution apparatus stems from the need to provide accurate, reliable data for decision-making during drug development stages and assurance of quality when the formulation reached full-scale production, as well as to maintain future assurance of product quality and stability.This topic will explore the use and general limitations of typical compendial USP apparatus, noncompendial modifications to the standard USP apparatus, and non-USP apparatus designed to yield small-volume dissolution methods with reliable results.In addition, related issues concerning apparatus calibration, method development, and method validation of the modified dissolution apparatus will be reviewed.
No takes yet. Share an insight, caveat, or question.
G. Bryan Crist (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: