Answers are grounded in this paper and cite their sources.
A dual-parameter optical fiber sensor is proposed and demonstrated. It is based on an intermodal interferometer (IMI) with an inline embedded fiber Bragg grating (FBG). The IMI is formed by cascading a taper structure and a spherical-shaped structure through a segment of a single-mode fiber. Due to the different wavelength shifts of the IMI and FBG to temperature and liquid level, simultaneous measurement can be achieved. Experimental results indicate a good linear relation between the wavelength shift and external parameters (temperature and liquid level). The sensitivities of 0.066 nm/°C and −0.133 nm/mm are achieved experimentally for temperature and liquid level, respectively. The interesting properties of the sensor include good operation linearity, compact size, and high sensitivity.
No takes yet. Share an insight, caveat, or question.
Luan et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: