Key result
Combined PFA plus LAAO is linked to ~9-fold higher significant peridevice leak versus standalone LAAO.
Why the study?
Combining pulsed field ablation and left atrial appendage occlusion into one procedure is appealing but comparative outcome data are lacking.
Does combined PFA and LAAO increase the risk of peridevice leak compared to standalone LAAO in patients with atrial fibrillation?
Cohort (n=136)
Yes
Does combined PFA and LAAO increase the risk of peridevice leak compared to standalone LAAO in patients with atrial fibrillation?
Combining PFA and LAAO in a single procedure causes acute pulmonary ridge swelling that significantly increases the risk of >3 mm peridevice leak at 3 months compared to standalone LAAO.
Answers are grounded in this paper and cite their sources.
Combined PFA-LAAO was associated with higher significant PDL; leaves open optimal sequencing in prospective trials.
BACKGROUND: Combining pulsed field ablation (PFA) and left atrial appendage occlusion (LAAO) to 1 procedure is appealing for the treatment of atrial fibrillation. OBJECTIVE: This study aimed to compare the outcome of combined and standalone procedures. METHODS: This is a retrospective cohort study of consecutive patients undergoing combined PFA and LAAO procedures in 3 centers in 2023. They underwent PFA pulmonary vein isolation (PVI) with Farapulse (Boston Scientific, Marlborough, MA), followed by LAAO with WATCHMAN FLX (Boston Scientific) guided by transesophageal echocardiogram (TEE). Pulmonary ridge thickness was measured at 45 degrees, 5 mm from tip of the ridge, before and after PFA. At 3 months, TEE or computed tomography was performed for patients with LAAO to assess occlusion results. Peridevice leak (PDL) of more than 3 mm was defined as significant. Consecutive PFA or LAAO standalone procedures served as controls. RESULTS: This cohort included 36 combined, 48 standalone LAAO, and 52 standalone PFA cases. Acute PVI was achieved in all combined and PFA standalone procedures. Successful LAAO implantation with WATCHMAN FLX was achieved in 97.2% combined procedures and all standalone LAAO procedures. In the combined cohort, pulmonary ridge thickness increased after ablation by 2.72 ± 1.19 mm (P < .001) or 69.4% ± 51.4%. At 3 months, the rate of PDL did not differ between combined and standalone LAAO cohorts (26.7 vs 15.2%, P = .22). However, significant PDL (> 3 mm) occurred more commonly in the combined cohort compared with the standalone LAAO cohort (20% vs 2.2%, P = .013). CONCLUSION: Combined PFA and LAAO was feasible. However, we observed a mean 69.4% increase in pulmonary ridge thickness immediately following PFA. Significant PDL was more prevalent in combined procedure.
No takes yet. Share an insight, caveat, or question.
Tam et al. (2025) conducted a cohort in Atrial fibrillation (n=136). Combined pulsed field ablation (PFA) and left atrial appendage occlusion (LAAO) vs. Standalone PFA or standalone LAAO was evaluated on Significant peridevice leak (> 3 mm) at 3 months (p=0.013). Combined PFA and LAAO was associated with a higher rate of significant peridevice leak (>3 mm) at 3 months compared to standalone LAAO (20% vs 2.2%, P=0.013).
Synapse has enriched 10 related papers. Consider them for comparative context: