Key result
PFA achieves 100% PVI in patients with prior LAA occlusion without new leaks or thrombus.
Why the study?
Experience with pulsed field ablation in patients with a prior left atrial appendage occlusion device is limited.
Is pulsed field ablation safe and feasible in patients with a prior left atrial appendage occlusion device?
Cohort (n=73)
Is pulsed field ablation safe and feasible in patients with a prior left atrial appendage occlusion device?
Pulsed field ablation is feasible and safe in patients with prior LAA occlusion devices, though operators must be aware of potential system shortages and rare fibrin apposition during LAA isolation.
Answers are grounded in this paper and cite their sources.
Demonstrates technical feasibility of left PV isolation; leaves open durability, safety, and outcomes in randomized trials.
Background Experience on pulsed field ablation (PFA) in patients with a prior left atrial appendage (LAA) occlusion device is limited. Purpose This study aimed to assess the feasibility and safety of PFA in patients with an implanted LAA occlusion device. Methods We analyzed 73 consecutive patients with a prior LAA occlusion device who underwent PFA with either pentaspline and lattice tip catheters system between February 2024 and September 2025. The efficacy endpoint was defined as successful isolation of left pulmonary veins (PV) or of the LAA, while the safety endpoint included system shortage due to EMI and new peri-device leaks (PDLs), device-related thrombus (DRT) during follow-up. Results PFA was performed using the pentaspline and lattice tip catheters in 45 (61.6%) and 28 (38.4%) respectively. The efficacy endpoint was achieved in all during PVs isolation. LAA isolation was successfully performed in 5 patients using the pentasline catheters and in 15 patients using the lattice tip catheters. However, during LAA isolation, in the pentaspline group, EMI prevented energy delivery in 3(60%) patients, while in the lattice tip group, bubble formation related to energy delivery shortage occurred in 3(20%) patients; upon removal of the lattice tip catheters from the left atrium, fibrin deposition was observed in 2 of these cases. At 3-months transoesophageal echocardiography follow-up, no new PDLs or DRT were detected. Conclusion Our findings suggest that PFA in patients with an implanted LAA occlusion device is safe and feasible. However, attention should be paid to system shortages, as, in rare cases, this can result in fibrin apposition.
No takes yet. Share an insight, caveat, or question.
Marino et al. (2026) conducted a cohort in Prior left atrial appendage occlusion device undergoing pulsed field ablation (n=73). Pulsed field ablation was evaluated on Successful isolation of left pulmonary veins or of the left atrial appendage. Pulsed field ablation achieved 100% successful pulmonary vein isolation in patients with a prior LAA occlusion device, with no new peri-device leaks or device-related thrombus at 3 months.