Answers are grounded in this paper and cite their sources.
We have introduced the swirling test as a routine quality control of individual platelet concentrates (PC), in use since 1995. Of PC (127, 623 bags) examined in the last six years, 82 (0.064%) failed the swirling test. The swirling-negative PC bags tended to be obtained when 1) a certain apheresis machine was used for PC collection, 2) the PC donor was female and 3) the PC was obtained from a donor whose PC was swirling-negative at a previous donation. Of 141 PC donation from 12 such donors, 36 PC bags (25.5%) showed negative swirling.While swirling-negative PCs showing normal pH originally maintained their normal range for five days, the extent of their platelet shape change and morphology scores were significantly lower than those of normal PCs. There were no significant differences in aggregation activity or in the expression of activation markers (P-selectin and beta-TG).The cause of this type of negative swirling is unknown at present. The fact that PCs repeatedly showed negative swirling from the same donors suggest that a factor (s) of the donors may be associated with the loss of swirling.
No takes yet. Share an insight, caveat, or question.
Akino et al. (2003) studied this question.