This is the authors' abstract. We don't add key points for this paper.
In VVER-1000/1200 type reactors much higher and geometrically more complex assemblies are applied compared to the VVER-440 design. Additionally, assembly shrouds are not used in the improved reactor types. This implies that the existing sub-channel wise models and hot channel calculation methodologies used in the safety assessment of VVER-440 reactors have to be improved. For this purpose a full core thermal hydraulic model was developed. In the first part of the paper the new model and its connections with the reactor physics of KARATE-1200 code system are demonstrated with results regarding the sub-channel outlet temperature and DNBR. In the second part of the paper the hot channel calculation methodologies to be used in the transient safety analyses of VVER-1200 type reactors are discussed. The appropriate frame parameter concept concerning the limitation of the heating up of the coolant and the single closed sub-channel approach vs. the multi-channel approach are studied, as well.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Panka et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: