Key result
Von Neumann entropy extraction slightly boosts key strength by ~8% but increases generation time 2.5-fold.
Why the study?
Low randomness in the most-significant bits of Inter-Pulse-Interval data limits the effectiveness of heart-beat-based security key generation.
Applying a von Neumann extractor to heart-beat-based security keys increases randomness but also increases inter-key disparity and generation time, resulting in only marginal improvements in effective key strength.
Answers are grounded in this paper and cite their sources.
May not justify von Neumann extraction for heartbeat-based keys given time costs; leaves open whether refined methods can enhance biometric device security.
The Inter-Pulse-Interval (IPI) of heart beats has previously been suggested for facilitating security in mobile health (mHealth) applications. In heart-beat-based security, a security key is derived from the time difference between consecutive heart beats. As two entities that simultaneously sample the same heart beats may generate the same key (with some inter-key disparity), these keys may be used for various security functions, such as entity authentication or data confidentiality. One of the key limitations in heart-beat-based security is the low randomness intrinsic to the most-significant bits (MSBs) in the digital representation of each IPI. In this paper, we explore the use of a von Neumann entropy extractor on these MSBs in order to increase their randomness. We show that our von Neumann key-generator produces significantly more random bits than a non-extracting key generator with an average bit-extraction rate between 13.4% and 21.9%. Despite this increase in randomness, we also find a substantial increase in inter-key disparity, increasing the mismatch tolerance required for a given true-key pair. Accordingly, the maximum-attainable effective key-strength of our key generator is only slightly higher than that of a non-extracting generator (16.4 bits compared to 15.2 bits of security for a 60-bit key), while the former requires an increase in average key-generation time of 2.5x.
No takes yet. Share an insight, caveat, or question.
Seepers et al. (2015) studied this question. von Neumann entropy extractor on MSBs of IPI vs. non-extracting key generator was evaluated on effective key-strength for a 60-bit key. Using a von Neumann entropy extractor on heart-beat inter-pulse-intervals slightly increased effective key-strength but required a 2.5x increase in average key-generation time.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: