Key result
Infants under 3 months with congenital heart disease show faster clotting and greater clot firmness.
Why the study?
Reference intervals for thromboelastometric evaluation of coagulation in pediatric patients with congenital heart diseases were not established.
What are the reference intervals for ROTEM parameters in pediatric patients with congenital heart diseases?
Observational (n=413)
What are the reference intervals for ROTEM parameters in pediatric patients with congenital heart diseases?
Pediatric patients with congenital heart disease have functionally intact coagulation profiles before surgery, with ROTEM reference intervals showing similar patterns to healthy pediatric patients.
Supports age-specific ROTEM references in young infants with CHD; leaves open effects on perioperative transfusion decisions.
BACKGROUND Rotational thromboelastometry (ROTEM®) is a point-of-care test for coagulation, enabling physicians to make a swift decision. The aim of this investigation was to establish reference intervals of thromboelastometric evaluation for coagulation in pediatric patients with congenital heart diseases (CHD). MATERIAL AND METHODS As baseline data, 3 assays of ROTEM® (INTEM, EXTEM, and FIBTEM) were measured after anesthesia induction. ROTEM® parameters were clotting time (CT), amplitude at 10 min (A10), clot formation time (CFT), a angle, maximal clot firmness (MCF), clot lysis index at 60 min (LI60), and maximal clot elasticity (MCE). As age is a well-known factor for maturation, age groups were determined as follows; 1) <1 month, 2) 1-3 months, 3) 4-12 months, 4) 1-3 years, 5) 4-6 years, 6) 7-12 years, and 7) 13-16 years. Reference limits representing 95% of distribution of ROTEM® parameters and 90% confidence intervals of upper and lower reference limits were calculated. RESULTS The data of 413 patients were analyzed. Although INTEM CT was prolonged, significantly shorter CT and CFT, steeper α, and greater A10, MCF, and MCE were shown in patients age <3 months compared to older children. CONCLUSIONS Reference intervals of thromboelastometric evaluation for coagulation from pediatric patients with CHD were shown to have similar pattern to those obtained from healthy pediatric patients. Pediatric patients with CHD, even with cyanosis, were demonstrated to have functionally intact coagulation profile before surgery.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2016) conducted an observational in Congenital heart diseases (CHD) (n=413). Age <3 months vs. Older children was evaluated on ROTEM parameters (CT, A10, CFT, α angle, MCF, LI60, MCE). Pediatric patients with congenital heart diseases aged <3 months exhibited significantly shorter clotting times and greater clot firmness on ROTEM compared to older children.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: