Answers are grounded in this paper and cite their sources.
Aims Computer-aided detection (CADe) and diagnosis (CADx) systems such as CAD EYE (EX-1, Fujifilm), launched in 2020, have been widely adopted worldwide and demonstrated significant value in colorectal neoplasia detection and characterization 1,2). In 2024, a new endoscopy system, EP-8000 (Fujifilm), became available, providing brighter images with reduced halation and improved contrast 3). In the same year, a new CAD EYE software version with a 1.6-fold larger training dataset and improved performance was released. This study aimed to evaluate the detection and diagnostic performance of CAD EYE with the EP-8000 system and compare the results with those obtained using the previous system (VP-7000) and the earlier software version. Methods This single-center observational study included consecutive colorectal lesions (2–10 mm) detected by expert endoscopists using EP-8000 from March to May 2025. After lesion recognition by the endoscopist, CAD EYE was activated. White-light imaging (WLI) and linked color imaging (LCI) with and without 1.5×high-speed scanning (high-speed WLI/LCI), including approximately 3 cm of surrounding mucosa, were evaluated for CADe performance. Positive detection was defined as the accurate appearance of an annotation box on the lesion. CADx performance was evaluated using CAD EYE-assisted BLI-magnifying observation and compared with subsequent histopathology. Outcomes were compared with 100 previously evaluated lesions obtained under VP-7000 using the same methodology [ 1 ] [ 2 ] [ 3 ]. Results A total of 27 patients with 100 lesions were analyzed (mean age 66.7±10.9 years; males 66.7%). Mean tumor size was 4.2±2.7 mm; proximal colon 46.0%; protruded type 41.0%. Histology included sessile serrated lesions and low-grade adenomas: 57 and 43 lesions, respectively. Detection rates were: WLI 94.0% vs. high-speed WLI 68.0% (p<0.001), LCI 94.0% vs. high-speed LCI 75.0% (p<0.001), WLI 94.0% vs. LCI 94.0% (p=1.000), and high-speed WLI 68.0% vs. high-speed LCI 75.0% (p=0.273).CADx accuracy was 95.0%, slightly lower than expert BLI-magnifying diagnosis (100.0%, p=0.06). Comparisons with VP-7000 showed no differences in lesion characteristics, while CADe was significantly improved under EP-8000 in WLI: 94.0% vs. 85.0% (p=0.038). Other detection modes showed comparable performance. CADx accuracy tended to improve: 95.0% vs. 87.8% (p=0.080). Importantly, false-positive alarms per case were significantly reduced with EP-8000: 12.4±7.9 vs. 19.5±13.4 (p=0.020). Conclusions CAD EYE with the new EP-8000 system demonstrated improved detection and diagnostic performance compared to the previous system, along with fewer false alarms. Further data accumulation is ongoing to strengthen these findings. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
No takes yet. Share an insight, caveat, or question.
Yoshida et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: