Key result
SAPIEN 3, Evolut R, and ACURATE neo yield similar 1-year MACCE, but Evolut R requires more pacemakers.
Why the study?
Few head-to-head comparisons are available among new-generation transcatheter aortic valve prostheses despite their improved procedural outcomes.
Do different new-generation transcatheter aortic valve prostheses (SAPIEN 3, Evolut R, ACURATE neo) have different clinical and echocardiographic outcomes in patients with severe aortic stenosis?
Population
346 patients undergoing elective TF-TAVI for native, severe aortic stenosis
Comparison
Edwards SAPIEN 3 vs Medtronic Evolut R vs Boston ACURATE neo prostheses
Design
Single-center retrospective cohort study with propensity score weighting
Follow-up
1 year
Authors
Loading...
Similar MACCE rates may allow flexible valve selection; Evolut R-associated higher pacemaker rates leave open comparative safety in observational cohorts.
Cohort (n=389)
No
Do different new-generation transcatheter aortic valve prostheses (SAPIEN 3, Evolut R, ACURATE neo) have different clinical and echocardiographic outcomes in patients with severe aortic stenosis?
p-value: p=0.534
New-generation TAVI devices offer comparable 1-year clinical outcomes, but differ significantly in rates of pacemaker implantation and paravalvular regurgitation.
Costa et al. (2019) conducted a cohort in Native, severe aortic stenosis (n=389). Edwards SAPIEN 3, Medtronic Evolut R, or Boston ACURATE neo vs. Head-to-head comparison was evaluated on 1-year major adverse cardiovascular and cerebrovascular events (MACCE) (p=0.534). TAVI using SAPIEN 3, Evolut R, and ACURATE neo valves yielded similar 1-year MACCE rates (P=0.534), but Evolut R had higher pacemaker implantation rates (16.7% vs 8.3% and 2.1%; P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: