Answers are grounded in this paper and cite their sources.
In the setting of ethylene glycol (EG) poisoning, a falsely elevated serum lactate concentration is suggested to be an assay cross-reaction with glycolate, but a concentration-dependent relationship has never been identified. We correlate serum lactate and glycolate concentrations in a case of severe EG poisoning. Serial EG [by gas chromatography (GC)], glycolate (derivatized to methyl glycolate, analysis by GC), and lactate (both enzymatic spectrophotometry and GC) concentrations were correlated at five time points. False-positive lactate was confirmed by absence of lactate on GC analysis. The correlation coefficient (Pearson's r) between lactate (by enzymatic spectrophotometry) and glycolate was 0.984 and was statistically significant (p < 0.01). The mean lactate/glycolate conversion factor was 2.58 +/- 0.95. We demonstrate the linear correlation between falsely elevated serum lactate and glycolate concentrations in a case of severe EG poisoning. Our data provide further support to the belief that the lactate assay may cross-react with glycolate in EG poisoning.
No takes yet. Share an insight, caveat, or question.
Manini et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: