A thermal system for nondestructive detection of broken fibers in unidirectional carbon fiber composites is described. The sample is heated inductively so that a line-shaped coil is scanned in the direction of the fibers. Since the thermal conductivity along the fibers is much better than in the perpendicular direction, the heat generated flows mainly in the scanning direction. Thus, the broken fibers hinder the heat flow effectively. They can be detected by monitoring the thermal radiation from the sample surface using an infrared line scanner, the image line of which is synchronized with the heating line in order to record a two-dimensional thermal image. The effect of broken fibers on the surface temperature of unidirectional carbon fiber composites is evaluated numerically and the feasibility of the system is verified experimentally.
No takes yet. Share an insight, caveat, or question.
Varis et al. (1997) studied this question.