Key result
The spectral power of the very high frequency band of instantaneous pulse rate variability decreased during head-up tilt and increased during passive leg raising compared to baseline.
Why the study?
Does instantaneous pulse rate variability (iPRV) using frequency domain analysis indicate fluid responsiveness during head-up tilt and passive leg raising in healthy subjects?
Observational (n=26)
No
Does instantaneous pulse rate variability (iPRV) using frequency domain analysis indicate fluid responsiveness during head-up tilt and passive leg raising in healthy subjects?
Instantaneous pulse rate variability (iPRV) using frequency domain analysis provides a potential physiological indicator for assessing fluid responsiveness.
Answers are grounded in this paper and cite their sources.
Very high frequency pulse rate variability responds to postural maneuvers; hypothesis-generating for autonomic monitoring pending prospective validation.
In the ICU, fluid therapy is conventional strategy for the patient in shock. However, only half of ICU patients have well-responses to fluid therapy, and fluid loading in non-responsive patient delays definitive therapy. Prediction of fluid responsiveness (FR) has become intense topic in clinic. Most of conventional FR prediction method based on time domain analysis, and it is limited ability to indicate FR. This study proposed a method which predicts FR based on frequency domain analysis, named instantaneous pulse rate variability (iPRV). iPRV provides a new indication in very high frequency (VHF) range (0.4-0.8Hz) of spectrum for peripheral responses. Twenty six healthy subjects participated this study and photoplethysmography signal was recorded in supine baseline, during head-up tilt (HUT), and passive leg raising (PLR), which induces variation of venous return and helps for quantitative assessment of FR individually. The result showed the spectral power of VHF decreased during HUT (573.96±756.36 ms2 in baseline; 348.00±434.92 ms2 in HUT) and increased during PLR (573.96±756.36 ms2 in baseline; 718.92±973.70 ms2 in PLR), which present the compensated regulation of venous return and FR. This study provides an effective indicator for assessing FR in frequency domain and has potential to be a reliable system in ICU.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2016) conducted an observational in Healthy subjects (assessing fluid responsiveness) (n=26). Head-up tilt (HUT) and passive leg raising (PLR) vs. Supine baseline was evaluated on Spectral power of very high frequency (VHF) band (0.4-0.8Hz) of instantaneous pulse rate variability during head-up tilt (p=<0.05). The spectral power of the very high frequency band of instantaneous pulse rate variability decreased during head-up tilt and increased during passive leg raising compared to baseline.