This is the authors' abstract. We don't add key points for this paper.
Preventable healthcare-associated infection (HCAI) remains a significant problem, with the Centers for Disease Control and Prevention (CDC) estimating 1.7 million infections in US hospitals and 99,000 associated deaths per annum.1 Vascular access devices (VADs), especially, provide a direct invasive route for microorganisms to infect patients during their insertion and ongoing maintenance, and consequently they provide a relatively high risk of preventable morbidity and mortality. The CDC estimates the cost of central line–associated bloodstream infections were close to $3 billion per annum in 2007.2Consequently, for all invasive clinical procedures and ongoing maintenance of indwelling medical devices, patients are dependent upon healthcare workers (HCWs) and healthcare organizations to protect them from infection. This is only ensured when a collection of infection prevention methods and actions, generically referred to as aseptic or sterile techniques, are applied effectively. Effective aseptic technique is particularly important for patient safety during the insertion and maintenance of implanted vascular access devices due to their particularly invasive nature and frequent use. The challenge for healthcare organizations worldwide is to ensure effective aseptic technique for every invasive clinical procedure on every occasion.Despite its importance, the literature and education for aseptic technique is historically ambiguous, with conflicting approaches utilizing confused and interchangeable terminologies.3–5 Consequently, there is a dearth of research and highly variable and often poor standards of care, all contributing to preventable HCAI.6–9The historical picture becomes even more concerning in light of an international review by the Association for Safe Aseptic Practice (ASAP) in 2019 that identified international stake-holder guidance near universally “prescribed” aseptic technique with virtually no description of what aseptic technique is or how it needs to be applied to ensure patient safety.10–12 The problem of prescription without description for aseptic technique has similarly been reflected in equipment-focused standardized bundles of care. As a result, benefits seen in this approach for specific procedures such as central venous access device insertion1314 have not had wider influence on other aseptic procedures that remain problematic and of concern. For example, Mermel and DeVries1516 have highlighted a particular concern with standards of care afforded to peripheral intravenous venous catheter (PIVC) insertion and its ongoing maintenance. Reflecting this concern and need for improvement, the ECRI Institute identified infections from PIVCs in their report “Top 10 Patient Safety Issues for 2019.”17The ANTT clinical practice framework outlined here was originated by Rowley1819 as a contemporary clinical practice framework for aseptic technique and has been shown to support reductions in HCAI.20–23 The National Institute for Health and Care Excellence defined ANTT's original concept of Key-Part and Key-Site Protection as being “a specific type of aseptic technique with a unique theory and practice framework.”10 Notably, ANTT is designed to be used in all settings for all clinically invasive procedures, from complex surgery to simple maintenance procedures. It is now used extensively in all care settings in over 30 countries and is increasingly being mandated by governments within national standards.2425Using the ANTT clinical practice framework affords health-care organizations a number of advantages that support improved patient safety.ANTT is overseen and disseminated by ASAP, a global nonprofit nongovernmental organization (NGO). The association works with individual HCWs, healthcare organizations, specialist organizations such as Association for Vascular Access (AVA), industry, and governments to support and facilitate the dissemination of a single global standard for aseptic technique with ANTT.ANTT's continued development as the single global standard for this critical clinical competency provides advantages for more meaningful and transferable education, practice, and research. ANTT implementation is based upon the premise that reducing the variables in aseptic practice across large clinical workforces by standardizing aseptic technique (Tables 1 and 2) logically supports improvements in patient safety and, subsequently, infection rates.18–202627ANTT needs to be efficient as well as safe. Therefore, although the principles are the same, there are two types of process for ANTT, as discussed below. Selection of Surgical-ANTT or Standard-ANTT is based upon ANTT risk assessment, according to the technical difficulty of ensuring Key-Part and Key-Site asepsis, not extraneous criteria such as the diagnosis or the age of the patient.Surgical-ANTT is used for clinically invasive procedures where achieving asepsis is technically difficut and/or procedures are long in duration, e.g., surgery, central line insertion, urinary catheterization. Surgical-ANTT typically involves a combination of standard precautions, full barrier precautions, and Critical Aseptic Field management (use of a sterilized drape).Standard-ANTT is used for clinically invasive procedures where achieving asepsis is technically straightforward and short in duration, e.g., peripheral cannulation or intravenous maintenance. Standard-ANTT typically involves a combination of standard precautions, a general aseptic field, and Key-Parts protected by Micro Critical Aseptic Fields and non-touch technique.Both Surgical-ANTT and Standard-ANTT are utilized for different intravenous therapy procedures.ANTT risk assessment involves the practitioner assessing the difficulty of maintaining asepsis of all Key-Parts. The practitioner determines that there are multiple Key-Parts requiring protection and significant manipulation, the procedure area is large, and/or the Key-Site (the insertion site) is particularly invasive. To maintain asepsis, Surgical-ANTT is required (Figure 1).ANTT risk assessment involves the practitioner assessing the difficulty of maintaining asepsis of all Key-Parts. The practitioner determines that there are few Key-Parts that are easily manipulated individually using non-touch technique. The procedure area is small, the Key-Site (the catheter exit site), while invasive, is protected by a sterilized dressing/fixation device. The Key-Part (the IV access port) is protected in part by a closed-circuit intravenous device. Therefore, to maintain asepsis, the more efficient Standard-ANTT is appropriate (Figure 2).A summary of the ANTT clinical practice framework is given in Figure 3.The advantages for patients in having a single international standard for the critical clinical competency of aseptic technique are as clear as they are profound. In collaboration ASAP, the AVA supports the important international patient safety initiative of having a single standard for aseptic technique, ANTT.Given the variability of facilities, personnel, organizational capabilities, and practices, AVA recommends the following.Given the ongoing concerns regarding the maintenance of VADs and increasing concerns regarding the insertion and maintenance of short peripheral cannulas, AVA recommends that healthcare organizations consider utilization of the international standard of ANTT.This document is meant to serve as a basis for evidence-based decision making. Nothing contained within this position paper should take the place of following a medical device's approved instructions for use provided by the manufacturer.AVA was founded in 1985 to promote the emerging vascular access specialty. Today, AVA stands at the forefront of protecting and saving lives via establishing best practices and promoting patient advocacy. AVA's multidisciplinary membership advances research, provides professional and public education to shape practice and enhance patient outcomes, and partners with the device manufacturing community to bring about evidence-based innovations in vascular access. To learn more or join, visit www.joinAVAnow.com.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Rowley et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: