Answers are grounded in this paper and cite their sources.
The treatment of nonhealing corneal epithelial defects and ulcers can be very challenging. The most frequently used surgical treatment is amniotic membrane transplantation (Schrader et al. 2009). While amniotic membrane supports adhesion and migration of corneal epithelial cells and has been shown to reduce inflammation, cicatrization and angiogenesis on the ocular surface (Dua et al. 2004; Schrader et al. 2009), its use involves several drawbacks such as its biological variability, limited availability, potential risk of disease transmission and costly screening processes (Dua et al. 2004; Jirsova & Jones 2017). Due to these limitations, many attempts have been made to develop a standardized substitute tissue to replace amniotic membrane. As the main component of the cornea, collagen shows many characteristics of an ideal substitute, such as high biocompatibility, low immunogenicity and its ability to support migration and adhesion of corneal epithelial cells (Levis et al. 2010). A considerable problem for the clinical use of a collagen-based matrix for ocular surface reconstruction is that collagen hydrogels contain large amounts of water and therefore are inherently weak. However, the biomechanical properties of collagen hydrogels can be improved using the process of plastic compression as introduced by Brown et al. (2005). In previous work, our group has shown that such plastic compressed collagen (PCC) matrices are a suitable substrate for the expansion of human conjunctival epithelial cells, and we could also show that PCC matrices have a high tensile strength, elasticity and excellent material properties for surgical handling in ocular surface transplantation (Drechsler et al. 2017). In this report, we describe the transplantation of a PCC matrix to the corneal surface in an 80-year-old woman, with a therapy-resistant corneal ulcer in her right eye due to neurotrophic keratopathy. The patient suffered from type II diabetes, which seemed to be the cause of the neurotrophic keratopathy. Central corneal sensitivity using the Cochet–Bonnet aesthesiometer was reduced in the right eye to 12.84 g/sq/mm (10 mm thread length) and in the left eye to 1.16 g/sq/mm (50 mm thread length). The corneal lesion had already been extensively treated with unpreserved artificial tears for 3 months, and the patient had undergone two amniotic membrane transplantations, which had been unsuccessful in closing the corneal defect. Due to the lack of alternative treatment options and after thorough risk-benefit assessment together with the patient, it was decided to transplant a PCC matrix to the corneal surface to support closure of the ocular surface defect. This new experimental treatment was performed as an ‘individual therapeutical attempt,’ carried out in accordance with the German Federal Medical Practitioners Act and in accordance with the Declaration of Helsinki (2013, Fortaleza, ‘Unproven Interventions in Clinical Practice’). A highly purified, biocompatible type I collagen derived from the porcine dermal skin with a triple-helical structure atelocollagen (EC CERTIFICATE No. 09 0456 QS/NB) CE-marked for clinical application (Cartifill™ 3%, RMS, Seoul, Korea), was used as a collagen source, and the PCC matrices were produced directly before surgery under sterile conditions in the tissue bank of the Department of Ophthalmology of the University of Duesseldorf as described before (Brown et al. 2005; Levis et al. 2010; Drechsler et al. 2017). One PCC matrix was transplanted inside the corneal defect (inlay) as a substrate for the corneal epithelium and as second matrix was used as a bandage (onlay) for the ocular surface and fixed with fibrin glue. One week after the surgery, the examination revealed a complete degradation of the PCC onlay, while the inlay was still in place and completely covered by epithelium. The inlay slowly degraded over time, but 26 weeks after surgery parts of the PCC matrix were still visible. The epithelial surface remained closed at the end of the follow-up period at 26 weeks (Fig. 1). No signs of toxicity or inflammatory response of the host site was noted. In conclusion, PCC matrices can be easily produced from CE marked atelocollagen and handled in ophthalmic surgery. To the best of our knowledge, this is the first case reporting successful ocular surface reconstruction using a PCC matrix in a patient with a nonhealing corneal ulcer.
No takes yet. Share an insight, caveat, or question.
Schrader et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: