Background Balance dysfunction is a common health issue among older adults and patients with neurological disorders. The Mini-Balance Evaluation Systems Test (Mini-BESTest) is a widely used clinical tool for balance assessment. However, its full implementation requires a trained clinician to administer 14 tasks, and the scoring is subject to inter-rater variability. Objective This study aims to develop an end-to-end, lightweight multimodal deep learning framework (with approximately 55 K parameters) to automatically predict the total Mini-BESTest score and its four subscale scores, utilizing only center of pressure (COP) signals from a single stance condition alongside clinical metadata. Methods COP signals and clinical metadata from 163 subjects in a public dataset (Santos et al., PeerJ, 2016, 4) were utilized. We proposed a lightweight multimodal deep learning model comprising three dilated convolution branches with varying dilation rates, a channel attention mechanism, and a metadata fusion module. Three independent comparative experiments were conducted to investigate the effects of stance condition, trial number, and time window length on predictive performance. Based on these results, a suitable data configuration was selected for subsequent experiments. An adaptive task weighting scheme based on homoscedastic uncertainty was employed to balance the five regression targets with varying score ranges. Five-fold cross-validation was used to evaluate the models, and out-of-fold (OOF) predictions were constructed to provide a full-sample assessment of predictive performance. Results Under the selected data configuration (foam surface with eyes open, second trial, first 30 s of data), the five-fold cross-validation mean absolute error (MAE) for the predicted Mini-BESTest total score was 1.971 (out of 28). The full-sample OOF prediction MAE was 1.979, with a Pearson correlation coefficient of r = 0.758 and R 2 = 0.574. In ablation experiments, removing the metadata branch led to the largest numerical increase in total-score MAE (to 2.338), while removal of the channel attention module resulted in a smaller increase (to 2.034). A metadata-only model achieved a total-score MAE of 2.105. Paired Wilcoxon signed-rank tests did not show statistically significant differences between the full model and the ablated variants (all p > 0.05). Conclusion This study demonstrates that an end-to-end deep learning framework can predict the complete Mini-BESTest score from 30 s of quiet standing COP signals under foam surface eyes-open conditions, together with basic clinical metadata. While maintaining predictive accuracy, this lightweight framework (approx. 55 K parameters) may represent a potential direction for future deployment in portable or remote settings, subject to further engineering and clinical validation.
No takes yet. Share an insight, caveat, or question.
Fan et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: