Answers are grounded in this paper and cite their sources.
This study evaluates and compares the mechanical performance and microstructures of dissimilar welded joints made from S355J2 + N and S690QL steels, using G69 and T46 fillers. Tensile, Charpy V-notch (CVN) impact, and hardness tests were conducted, along with optical microscopy and scanning electron microscopy (SEM) for microstructural and fractographic analysis. Average ultimate tensile strengths reached 540 ± 2.5 MPa for T46 and 524 ± 2.5 MPa for G69 joints, with all specimens fracturing within the weaker base metal (S355J2 + N) that had an ultimate tensile strength of 479 MPa, indicating successful overmatching with joint integrity. Hardness examination showed a peak value of 282 ± 3 HV in the S690QL-HAZ, attributed to the formation of martensite laths and localized tempered martensite. The G69 filler wire exhibited higher energy absorption ( 94 ± 13 J at − 20 ∘ C ) compared to the T46 wire ( 67 ± 23 J ). The T46 weld zone showed a higher density of brittle cleavage facets, likely due to the presence of M-A constituents. Despite the variances, all tested specimens fulfilled the minimum impact toughness requirement of 27 J at − 20 ∘ C according to EN 10025-2 standard for S355J2 + N structural steel, demonstrating that both filler wires are appropriate for high-strength dissimilar steel applications under the investigated conditions.
No takes yet. Share an insight, caveat, or question.
Akay et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: