This is the authors' abstract. We don't add key points for this paper.
Building-integrated photovoltaics (BIPVs) have been extensively studied in solar-rich regions, whereas the research in solar-poor regions remains limited, particularly regarding the combined assessment of economic and daylighting performance. This study investigated BIPV optimization for office buildings in solar-poor regions by jointly considering the net energy consumption (Enet), static payback period (SPP), and daylight autonomy (DA). Three representative building morphologies were identified through a cluster analysis. NSGA-II was used to generate Pareto-optimal solutions, and TOPSIS was applied to select representative compromise solutions using the building orientation (BO), window-to-wall ratio (WWR), photovoltaic transmittance (PVT), and photovoltaic coverage ratio (PVR) as the decision variables. The Pareto-optimal solutions were frequently concentrated at BO = 80–130°, WWR = 1.0, PVT = 30–40%, and PVR = 0.9–1.0. The PVR and PVT showed the strongest standardized associations with performance. Compared with the baseline cases, the representative solutions reduced the SPP by 8.34% and 11.94% for Types II and III, respectively, while Type I remained nearly unchanged. The DA increased by 4.58–15.46%. These results demonstrate morphology-dependent trade-offs and provide a transferable framework for BIPV façade optimization in solar-poor regions.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: