Key result
Sutureless AVR shows similar safety to TAVI but is associated with a deeper ~66% platelet decline.
Why the study?
Evidence specific to Perceval Plus sutureless aortic valve replacement remains limited regarding postoperative clinical outcomes and hematological and inflammatory dynamics compared to TAVI.
Does Sutureless Aortic Valve Replacement (Perceval Plus) alter postoperative clinical outcomes and hematological/inflammatory dynamics compared to TAVI in patients with severe aortic stenosis?
Cohort (n=154)
No
Does Sutureless Aortic Valve Replacement (Perceval Plus) alter postoperative clinical outcomes and hematological/inflammatory dynamics compared to TAVI in patients with severe aortic stenosis?
While Su-AVR and TAVI show similar short-term clinical safety for severe aortic stenosis, Su-AVR induces a more pronounced postoperative inflammatory response and platelet decline.
Answers are grounded in this paper and cite their sources.
Similar short-term outcomes with Su-AVR and TAVI; greater platelet and CRP changes with Su-AVR leave open need for prospective confirmation.
Perceval Plus and TAVI are increasingly used for severe aortic stenosis, both relying on a self-expanding nitinol stent design, yet evidence specific to Perceval Plus remains limited regarding postoperative clinical outcomes and hematological and inflammatory dynamics. We compared postoperative clinical outcomes and longitudinal platelet/CRP dynamics between Perceval Plus and TAVI in a retrospective single-center cohort, in which 26 propensity score-matched pairs were obtained (1:1 matching) from patients undergoing Su-AVR (Perceval Plus, n = 53) or TAVI (self-expanding Medtronic devices, n = 101). Mortality, echocardiographic outcomes, and rates of postoperative atrial fibrillation and conduction disturbances showed no statistically significant differences between groups, while TAVI was associated with shorter ICU and hospital stay and Su-AVR required higher FFP transfusion (p = 0.016). Platelet count declined in both groups, with a deeper nadir in Su-AVR (postoperative day 3: 66% decline) versus TAVI (day 4: 27% decline), with a significant group × time interaction (p = 0.013); CRP rose in both groups but more rapidly and to a greater magnitude in Su-AVR (time and group × time interaction, both p < 0.001). Su-AVR and TAVI showed no statistically significant differences in the clinical safety outcomes assessed but differed in postoperative hematological and inflammatory magnitude, likely reflecting multifactorial procedure- and device-related mechanisms, warranting confirmation in larger, prospective, multicenter studies.
No takes yet. Share an insight, caveat, or question.
Kahraman et al. (2026) conducted a cohort in Severe aortic stenosis (n=154). Sutureless Aortic Valve Replacement (Perceval Plus) vs. TAVI (self-expanding Medtronic devices) was evaluated on Postoperative platelet count decline (p=0.013). Sutureless aortic valve replacement with Perceval Plus showed similar clinical safety to TAVI but resulted in a deeper postoperative platelet nadir and greater CRP rise.
Synapse has enriched 10 related papers. Consider them for comparative context: