Flow-induced vibration (FIV) of fuel rods in axial coolant flow can drive grid-to-rod fretting and, in severe cases, lead to cladding failure, motivating high-fidelity fluid–structure interaction (FSI) analysis with improved computational efficiency. This study develops a partitioned framework that couples large-eddy simulation (LES) of the axial flow with a transfer-matrix and modal-superposition structural solver, where the fuel rod is modelled as an Euler–Bernoulli beam. The framework is verified on a clamped–clamped rod by comparison with an in-house finite element method (FEM) beam model, the Ansys APDL BEAM4 element, and the SOLID187 solid element. The first three natural frequencies and the root-mean-square (RMS) displacements at L /4, L /2, and 3 L /4 agree to within approximately 1% across all comparisons. The predicted displacement spectra accurately reproduce the first three structural modes and their orbital trajectories. Compared with the in-house FEM, the beam-based TMM structural solver reduces the structural computation time by about a factor of four at comparable accuracy for the present single-rod case, and its advantage is expected to grow for multi-span, grid-supported rod configurations, since the size of the transfer-matrix system is independent of the number of spans and lumped supports. Validation against the axial-flow-induced vibration experiment of Cioncolini et al. yields predictions of the first-mode frequency and RMS free-end displacement within 2.4% and 3% of the measurements, respectively.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.