Horizontal banding caused by illumination or sensor-response non-uniformity is a recurring problem in stitched line-scan measurements. Direct generative restoration can remove the visible bands, but it cannot by itself provide a traceable measurement because it may redraw specimen details. This study evaluates a hybrid design in which a local image-editing model creates a separate approximate clean reference for every raw measurement. The generated image is never returned as measurement data. Instead, its scanline intensity distributions are paired with those of the raw image, a robust quadratic response model is fitted for each scanline, and the model is inverted on the original high-bit-depth samples. A second deterministic pass estimates spatially varying periodic residual gain on a 9x9 grid and analytically composes it with the first model. On two available wafer scans, the periodic log-domain proxy was reduced by 99.31% and 98.30%, respectively. These results establish technical feasibility, but the small data set and absence of calibrated clean ground truth do not yet establish metrological accuracy.
No takes yet. Share an insight, caveat, or question.
Lehotai et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: