Key result
Insulin tolerance test glucose disappearance rate closely correlates with euglycemic clamp measurements in type 2 diabetes.
Why the study?
The validity of the plasma glucose disappearance rate (KITT) from the insulin tolerance test for evaluating insulin sensitivity in type 2 diabetes patients after insulin therapy was unclear.
Is the insulin tolerance test (ITT) a valid method for evaluating insulin sensitivity in patients with type 2 diabetes receiving insulin therapy?
Observational (n=154)
Is the insulin tolerance test (ITT) a valid method for evaluating insulin sensitivity in patients with type 2 diabetes receiving insulin therapy?
The insulin tolerance test is a valid method for evaluating insulin sensitivity in patients with type 2 diabetes even after insulin therapy.
Answers are grounded in this paper and cite their sources.
ITT correlation with clamp supports validity in insulin-treated T2D; leaves open prospective validation before clinical adoption.
AIMS/INTRODUCTION: To establish the validity of the plasma glucose disappearance rate (KITT), derived from an insulin-tolerance test (ITT), for evaluating the insulin sensitivity of patients with type 2 diabetes after insulin therapy. MATERIALS AND METHODS: In the first arm of the study, 19 patients with poorly controlled diabetes were treated with insulin and underwent an ITT and a euglycemic clamp test (clamp-IR). The relationship between the insulin resistance index, as assessed by both the clamp-IR and KITT tests, was examined. In the second arm of the study, the relationships between KITT values and various clinical parameters were investigated in 135 patients with poorly controlled diabetes, after achieving glycemic control with insulin. RESULTS: In study 1, a close correlation between KITT and the average glucose infusion rate during the last 30 min of the standard clamp-IR test (M-value) was noted (P < 0.001). In study 2, body mass index (P = 0.0011), waist circumference (P = 0.0004), visceral fat area (P = 0.0011) and the log-transformed homeostasis model assessment of insulin resistance value (P = 0.0003) were negatively correlated with the log-transformed KITT. High-density lipoprotein cholesterol (P = 0.0183), low-density lipoprotein cholesterol (P = 0.0121) and adiponectin (P = 0.0384) levels were positively correlated with the log-transformed KITT. CONCLUSIONS: The ITT is a valid and useful test for evaluating the insulin sensitivity of patients with diabetes, even after treatment with insulin.
No takes yet. Share an insight, caveat, or question.
Okita et al. (2013) conducted an observational in Type 2 diabetes (n=154). Insulin tolerance test (ITT) vs. Euglycemic clamp test was evaluated on Correlation between plasma glucose disappearance rate (KITT) and average glucose infusion rate (M-value) during standard clamp-IR test (p=<0.001). The plasma glucose disappearance rate derived from an insulin tolerance test closely correlated with the euglycemic clamp test M-value in patients with type 2 diabetes.