Key result
Simulated smartwatch algorithms track AF burden closely with implantable monitors, showing up to ~82% sensitivity.
Why the study?
The accuracy of wearable ECG-enabled smartwatches for monitoring AF recurrence and quantifying AF burden after catheter ablation is uncertain.
Do smartwatch-based AF detection algorithms accurately detect atrial fibrillation recurrence and estimate AF burden compared with implantable cardiac monitors in post-ablation patients?
Do smartwatch-based AF detection algorithms accurately detect atrial fibrillation recurrence and estimate AF burden compared with implantable cardiac monitors in post-ablation patients?
Smartwatch-based AF detection algorithms demonstrate strong correlation with ICM-derived AF burden and clinically good sensitivity for recurrence detection, outperforming conventional non-invasive strategies.
Smartwatch algorithms may enable scalable post-ablation AF monitoring; leaves open prospective validation against continuous ICMs before practice change.
AIMS: Wearable ECG-enabled smartwatches have been validated for atrial fibrillation (AF) screening, but their accuracy for monitoring AF recurrence and quantifying AF burden after catheter ablation is uncertain. To evaluate the simulated performance of three commercial smartwatch algorithms for AF recurrence detection and AF burden estimation compared with implantable cardiac monitors (ICMs). METHODS AND RESULTS: Using continuous ICM data from 346 patients in the CIRCA-DOSE trial, we simulated three smartwatch algorithms, assuming daytime wear (8:00 AM-10:00 p.m.). We also simulated commonly-used non-invasive intermittent rhythm monitoring strategies. Primary endpoints were sensitivity for arrhythmia recurrence and correlation with ICM-derived AF burden. Analyses were stratified by daily wear time and patient activity. AF recurrence occurred in 47.1% of patients. Simulated detection sensitivities were 82.2% (Apple Watch AF Burden), 70.6% (Apple Watch IRN), and 64.4% (Fitbit IHRD), compared with 15.8-64.6% for simulated intermittent AECG monitors. Wearables outperformed commonly-used Holter/patch monitoring strategies. AF burden correlation with ICM exceeded r = 0.97 for all algorithms. Among missed recurrences, median AF burden was <0.02%. Longer daily wear improved sensitivity (>90% with 24-hour use), whereas patient activity modestly reduced detection. CONCLUSION: Smartwatch-based AF detection algorithms demonstrate strong correlation with ICM-derived AF burden and clinically good sensitivity for recurrence detection, outperforming conventional non-invasive strategies. These findings support the integration of wearables as a scalable alternative for post-ablation rhythm monitoring.
No takes yet. Share an insight, caveat, or question.
Aguilar et al. (2025) studied Atrial fibrillation after catheter ablation (n=346). Simulated smartwatch algorithms (Apple Watch AF Burden, Apple Watch IRN, Fitbit IHRD) vs. Implantable cardiac monitors (ICMs) and intermittent AECG monitors was evaluated on Sensitivity for arrhythmia recurrence and correlation with ICM-derived AF burden. Simulated smartwatch algorithms detected atrial fibrillation recurrence with 64.4% to 82.2% sensitivity and strongly correlated with ICM-derived AF burden (r > 0.97).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: