This paper addresses equivalent circuit and magnetic saturation issues associated with synchronous machine modeling. In the proposed synchronous machine model, the rotor equivalent circuits are replaced by arbitrary linear networks. This allows for elimination of the equivalent circuit parameter identification procedure since the measured frequency response may be directly embedded into the model. Magnetic saturation is also represented in both the q- and d-axis. The model is computationally efficient and suitable for dynamic time-domain power system studies.
No takes yet. Share an insight, caveat, or question.
Aliprantis et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: