This is the authors' abstract. We don't add key points for this paper.
The ion composition of dual-species beams in synchrotrons is typically inferred from invasive measurements performed after beam extraction. This paper introduces a complementary noninvasive method to determine the ion composition of such beams directly inside the synchrotron. The approach is applicable to low- and medium-energy ion synchrotrons and to small relative mass-to-charge ratio offsets, typically at the 10 − 4 level. The method exploits dispersive orbit offsets between the two species and corresponding frequency corrections applied by the synchrotron rf radial regulation loop. This capability is of particular interest for ongoing research on online monitoring in carbon ion beam therapy using mixed He 4 2 + and C 12 6 + beams, which feature a relative mass-to-charge ratio offset of 0.065%. The proposed method is analytically derived and tested with particle tracking simulations using . Its applicability under realistic experimental conditions is demonstrated at the MedAustron facility using mixed He 4 2 + and C 12 6 + beams. The results show good agreement with independent postextraction measurements.
No takes yet. Share an insight, caveat, or question.
Anonymous et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: