Key result
In a high-altitude area (3,294 m), the diagnostic reference values for type I and type II respiratory failure were determined to be PaO2 < 46.9 mmHg and PaCO2 > 38.1 mmHg, respectively.
Observational (n=1,541)
No
In high-altitude areas (3294 m), the reference values for diagnosing type I and II respiratory failure are lower than at sea level, specifically PaO2 46.9 mmHg and PaCO2 38.1 mmHg, respectively.
Answers are grounded in this paper and cite their sources.
May support altitude-adjusted PaO2/PaCO2 thresholds for respiratory failure diagnosis; leaves open prospective validation before practice change.
The arterial blood gas (ABG) reference values determined at or near sea level may not be applicable in high-altitude areas. This study investigated the reference values of the ABG indexes for adult respiratory failure in the Tibetan Autonomous Prefecture in Yunnan Province, China. This prospective study enrolled adult patients with respiratory failure at the internal medicine department of Diqing Tibetan Autonomous Prefecture (altitude: 3294 m) in Yunnan province between November 2019 and March 2022. There were 112 cases of type I respiratory failure (median age of 56 years, 61 males) and 91 with type II respiratory failure (median age of 59 years, 42 males). The reference value of PaO 2 for type I respiratory failure was 46.9 mmHg (AUC 1.000, 95% CI 1.000–1.000, sensitivity and specificity of 100%, P < 0.001). The reference value of PaCO 2 for type II respiratory failure was 38.1 mmHg (AUC 0.871, 95% CI 0.823–0.920, sensitivity and specificity of 95.6% and 60.4%, respectively, P < 0.001). It might be recommended that the reference values of PaO 2 and PaCO 2 for type I and II respiratory failure be 46.9 and 38.1 mmHg, respectively, in high-altitude areas.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) conducted an observational in Adult respiratory failure (n=1,541). High altitude (3,294 m) residence vs. Healthy controls was evaluated on Diagnostic threshold of PaO2 for type I respiratory failure (AUC 1.000, 95% CI 1.000-1.000, p=<0.001). In a high-altitude area (3,294 m), the diagnostic reference values for type I and type II respiratory failure were determined to be PaO2 < 46.9 mmHg and PaCO2 > 38.1 mmHg, respectively.
Synapse has enriched 10 related papers. Consider them for comparative context: