Key result
Circuit miniaturization and autotransfusion linked to ~72% drop in donor blood for pediatric cardiac surgery.
Why the study?
Donor blood requirements for paediatric open heart surgery were high, and methods to reduce priming volume and blood transfusion needed evaluation.
Does a donor blood reduction programme including circuit miniaturisation and autotransfusion reduce blood requirements in children undergoing open heart surgery?
Observational
Does a donor blood reduction programme including circuit miniaturisation and autotransfusion reduce blood requirements in children undergoing open heart surgery?
Absolute Event Rate: 0.89% vs 3.2%
Miniaturisation of the perfusion circuit and autotransfusion can considerably reduce donor blood requirements in paediatric open heart surgery.
Supports blood conservation via miniaturization in pediatric cardiac surgery; leaves open need for randomized confirmation before practice change.
We started a programme of donor blood reduction for open heart surgery in children in 1983. At first, only meticulous surgical and perfusion techniques were used. Later, increased haemodilution was added. Miniaturisation of the perfusion circuit and introduction of blood taken prior from the patient further decreased donor blood requirements. In 1989, we used 0.89 l per patient compared to 3.2 l per patient in 1983. Miniaturisation of the circuit was tested in a pilot study on 30 children undergoing the Senning operation in 1988. Priming volume was reduced from 661 +/- 72 ml to 421 +/- 62 ml. In 1989, 167 out of 194 children (86%) received a clear prime. Ninety-seven of 100 children whose weight was over 15 kg received a clear prime: 55 did not require subsequent transfusion. Prime miniaturisation and autotransfusion can considerably reduce blood requirements for open heart surgery.
No takes yet. Share an insight, caveat, or question.
Honĕk et al. (1992) conducted an observational in paediatric cardiac surgery. Miniaturisation of the perfusion circuit and autotransfusion vs. Standard perfusion circuit (1983) was evaluated on Donor blood requirements per patient (liters). Miniaturisation of the perfusion circuit and autotransfusion reduced donor blood requirements for pediatric open heart surgery from 3.2 L per patient in 1983 to 0.89 L per patient in 1989.