Key result
Intentional non-abutting right atrial port tip positioning achieves 100% technical success without catheter dysfunction.
Why the study?
The safety and feasibility of intentionally positioning the catheter tip in the right atrium without abutment during TIVAP implantation were not established.
Observational (n=330)
No
Intentional catheter tip positioning in the right atrium without abutment during TIVAP implantation is a safe and feasible technique with a low incidence of thrombosis.
May support right atrial TIVAP tip positioning; leaves open need for randomized confirmation before practice change.
Purpose: To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods: We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results: All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion: Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.
No takes yet. Share an insight, caveat, or question.
Park et al. (2024) conducted an observational in Malignancies requiring chemotherapy via totally implantable venous access port (n=330). Intentional positioning of the catheter tip in the right atrium without abutment was evaluated on Successful catheter tip positioning without abutment or dysfunction. Intentional positioning of the totally implantable venous access port catheter tip in the right atrium without abutment was successful in 100% of patients, with a 0.6% incidence of thrombosis and no observed dysfunction.