Key result
Inspiration shifts central venous catheter tips ~9 mm cephalad compared with expiration.
Why the study?
The impact of the phase of respiration on central venous catheter tip position using cross-sectional imaging was not well characterized.
Does the phase of respiration impact central venous catheter tip position on CT imaging?
Observational (n=24)
Does the phase of respiration impact central venous catheter tip position on CT imaging?
Mean Difference: 9
p-value: p=0.001
Central venous catheter tip position varies significantly with respiratory motion, moving an average of 9 mm cephalad during inspiration, which should be considered during placement and imaging evaluation.
Respiratory phase should be noted in CVC tip assessment on CT; leaves open effects on placement protocols or complications.
Purpose To determine the impact of the phase of respiration on CVC tip position using cross-sectional imaging. Methods We retrospectively analyzed the CT scans of 24 consecutive patients (eight men and 16 women, mean age 56.3 years, range 18-79) who underwent a CT scan protocol that includes both imaging of the thorax in inspiration and expiration. Only patients with a central venous catheter and absence of any substantial pulmonary pathology that might affect lung volumes were included. Measurements of the catheter tip location and central venous structures were obtained from inspiratory and expiratory phase images in each patient and compared using the paired t test. Results The length of the SVC and superior mediastinum were significantly longer during inspiration compared to expiration (9 mm and 7 mm respectively, P<0.001 for both). The distance between the superior and inferior cavo-atrial junction did not change significantly with respiration. The catheter tip location moved on average 9 mm (range 0-25 mm) cephalad during inspiration compared to expiration (P=0.001) in relation to the superior cavoatrial junction. The amount of catheter tip movement correlated significantly with the degree of diaphragmatic excursion with respiration (R=0.58). During inspiration, the cavo-atrial junction was on average 11 mm inferior to the right cardiomediastinal angle observed on radiography, but was nearly identical during expiration (R=0.78, P<0.001). Conclusions The central catheter tip position varied significantly with respiratory motion, with a mean excursion of 9 mm. The right cardiomediastinal border demonstrated a strong correlation with the actual location of the superior cavo-atrial junction in expiration, but not in inspiration.
No takes yet. Share an insight, caveat, or question.
Pan et al. (2013) conducted an observational in Central venous catheter (n=24). Inspiration vs. Expiration was evaluated on Catheter tip location movement in relation to the superior cavoatrial junction (9 mm, p=0.001). During inspiration, the central venous catheter tip moved an average of 9 mm cephalad compared to expiration (P=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: