Key result
Scintillation detector measurements of 99Tcm-plasmin and 99Tcm-erythrocytes showed a close relationship in patients with and without DVT (P<0.01), indicating non-specific binding to the thrombus.
Why the study?
The diagnostic performance of 99Tcm-porcine plasmin compared to 99Tcm-labelled erythrocytes for deep vein thrombosis was unclear.
Does 99Tcm-porcine plasmin or 99Tcm-labelled erythrocytes accurately diagnose deep vein thrombosis compared to phlebography in patients with suspected DVT?
Cross-Sectional (n=20)
Does 99Tcm-porcine plasmin or 99Tcm-labelled erythrocytes accurately diagnose deep vein thrombosis compared to phlebography in patients with suspected DVT?
Answers are grounded in this paper and cite their sources.
99Tcm-plasmin is not specifically bound to DVT thrombi, and its clinical utility depends on secondary circulatory changes, while 99Tcm-erythrocytes show high specificity for proximal DVT.
In 20 patients with suspect deep venous thrombosis (DVT), scintillation detector measurements were performed over each leg during the first 60 min after intravenous injection of 99Tcm-porcine plasmin. Thereafter, 99Tcm-labelled autologous erythrocytes were injected i.v. and repeat measurements were performed. Finally, scintillation camera images of both legs were obtained. Phlebography was used as a reference method. A close relationship (P less than 0.01) was found between the scintillation detector measurements, both in patients with DVT (n = 11) and in patients without DVT (n = 9). Thus, 99Tcm-plasmin is not specifically bound to the thrombus. Rather the clinical utility of the test depends mainly on circulatory changes secondary to the thrombus. Scintillation camera images of 99Tcm-erythrocytes in the legs were not useful for diagnosis of DVT in the calves but showed a high specificity for DVT in the popliteal and femoral veins.
No takes yet. Share an insight, caveat, or question.
Edenbrandt et al. (1984) conducted a cross-sectional in Suspect deep venous thrombosis (DVT) (n=20). 99Tcm-porcine plasmin and 99Tcm-labelled erythrocytes vs. Phlebography was evaluated on Relationship between scintillation detector measurements of 99Tcm-plasmin and 99Tcm-erythrocytes (p=<0.01). Scintillation detector measurements of 99Tcm-plasmin and 99Tcm-erythrocytes showed a close relationship in patients with and without DVT (P<0.01), indicating non-specific binding to the thrombus.