Key result
Programmable Implantable Medication System delivers continuous infusion for up to ~3.8 years without failure.
Why the study?
This study was motivated by the need to describe the design features and pre-clinical performance of a variable rate implantable insulin infusion pump, the Programmable Implantable Medication System (PIMS).
Does the Programmable Implantable Medication System (PIMS) function reliably in a pre-clinical dog model?
Does the Programmable Implantable Medication System (PIMS) function reliably in a pre-clinical dog model?
The PIMS implantable insulin pump demonstrated long-term mechanical and electronic reliability in pre-clinical dog models, supporting its potential for clinical use.
Advances implantable insulin pump technology; leaves open clinical efficacy and safety in diabetes.
This report describes the clinically significant design features of a variable rate implantable insulin infusion pump, the Programmable Implantable Medication System (PIMS), and its function in pre-clinical trials. PIMS has a number of unique features, including a solenoid, pulsatile pump design requiring minimal power (less than 15 microwatts) and a less-than-atmospheric pressure reservoir. Two-way communication is accomplished by radiotelemetry. The implanted device stores programs, and records its own hourly history of insulin delivery. Limits are set on total insulin delivery over time. Basal rates are adjustable, and patterned prandial insulin delivery curves can be programmed. Initial trials (3.1 dog-years) identified four problems which were corrected prior to final pre-clinical trials: microcracks in the diaphragm, a valve-seating leak, electronic failure of prototype microchips, and insulin aggregation. Sixteen dog-years of final pre-clinical trials with a single system design demonstrated that 5 pumps were still working continuously after up to 3.75 years (mean 3.3 years) without mechanical or electronic pump failure. The longest interval between reservoir refills was 5 months. Remaining potential causes of flow stoppage, however, include blockage of the peritoneal catheter by omentum (which occurred once), and air lock (which occurred two times).
No takes yet. Share an insight, caveat, or question.
Saudek et al. (1990) studied this question. Programmable Implantable Medication System (PIMS) was evaluated on Continuous pump function without mechanical or electronic failure. The Programmable Implantable Medication System (PIMS) functioned continuously in 5 dogs for up to 3.75 years (mean 3.3 years) without mechanical or electronic pump failure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: