Key result
Elevated BMP10 is linked to ~53% higher risk of AF recurrence after catheter ablation.
Why the study?
Biomarkers of atrial cardiomyopathy such as BMP10 may improve prediction of AF recurrence after catheter ablation, but evidence is limited and not comprehensively synthesized.
Do elevated circulating BMP10 levels predict recurrence of atrial fibrillation after catheter ablation?
Meta-Analysis (n=1,904)
Yes
Do elevated circulating BMP10 levels predict recurrence of atrial fibrillation after catheter ablation?
Hazard Ratio: 1.53 (95% CI 1.13–2.07)
p-value: p=0.006
Elevated circulating BMP10 levels may serve as a biomarker to predict a higher risk of atrial fibrillation recurrence following catheter ablation.
May aid post-ablation AF recurrence risk stratification; leaves open whether BMP10 improves prediction beyond clinical factors in prospective trials.
Background: Biomarkers of atrial cardiomyopathy may improve the prediction of recurrence of atrial fibrillation (AF) after catheter ablation. Bone morphogenetic protein-10 (BMP10) is an atrial-specific cardiomyocyte protein and a potential biomarker, but evidence is limited and not comprehensively synthesized. Methods: We performed a systematic review and meta-analysis of prospective cohort studies to evaluate the association between circulating BMP10 concentrations with AF recurrence after catheter ablation. Pooled hazard ratios (HRs) with corresponding 95% confidence intervals (CIs) were computed using a random-effects model. The primary analysis used unadjusted HRs per continuous BMP10 levels from all included studies. Secondary analyses were conducted based on the adjusted HRs of studies with continuous BMP10 and all studies, including one study that reported adjusted HRs based on quartiles. Results: Three studies were included. In the primary analysis without adjustment (n = 3), increased levels of BMP10 were significantly associated with recurrence of AF (pooled HR 1.53, 95% CI 1.13–2.07; P = 0.006), with moderate-to-high heterogeneity (I2 = 69%). The association was attenuated and non-significant in the adjusted analysis of two studies with continuous BMP10 (HR 1.46, 95% CI 0.94–2.25; I2 = 59%). However, after the inclusion of a third study with adjusted quartile-based HR, the statistical significance was re-demonstrated (HR 1.33, 95% CI 1.16–1.53; P < 0.001) with low heterogeneity (I2 = 20%). Conclusion: Elevated BMP10 levels are correlated with higher risk of AF recurrence following catheter ablation. Although the results are consistent across analyses, they should be interpreted with caution due to the small number of studies and methodological heterogeneity. BMP10 needs to be confirmed as a clinically applicable biomarker by larger prospective studies.
No takes yet. Share an insight, caveat, or question.
Mohsin et al. (2026) conducted a meta-analysis in Atrial fibrillation (n=1,904). Elevated Bone Morphogenetic Protein-10 (BMP10) vs. Lower BMP10 levels was evaluated on Atrial fibrillation recurrence after a 3-month post-ablation blanking period (HR 1.53, 95% CI 1.13-2.07, p=0.006). Elevated circulating BMP10 levels were significantly associated with a higher risk of atrial fibrillation recurrence following catheter ablation (pooled HR 1.53).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: