Key result
Elevated NT-proBNP prompts echocardiographic diagnosis of culture-negative pacemaker endocarditis guiding successful lead extraction.
Why the study?
Infective endocarditis presents diagnostic challenges due to variable clinical presentation and blood culture negativity, requiring integration of imaging and clinical findings.
Does echocardiography prompted by elevated NT-proBNP improve the detection of blood culture-negative infective endocarditis in a patient with a CIED and persistent fever?
Case Report (n=1)
Does echocardiography prompted by elevated NT-proBNP improve the detection of blood culture-negative infective endocarditis in a patient with a CIED and persistent fever?
Elevated NT-proBNP can serve as a critical clue prompting echocardiography to diagnose clinically elusive blood culture-negative endocarditis in high-risk patients with cardiac implantable electronic devices.
May prompt echocardiography for occult CIED endocarditis in febrile patients with elevated NT-proBNP; hypothesis-generating case leaves broader adoption open.
Infective endocarditis (IE) poses a known diagnostic challenge due to its variable clinical presentation. High suspicion for IE is generally driven by fever and positive blood cultures in the absence of an alternative focus of infection. We report an adult woman with a permanent pacemaker who presented with persistent fever, pleuritic chest pain and productive cough, diagnosed with right‐sided community‐acquired pneumonia. Blood cultures were negative; blood tests showed elevated inflammatory markers and an elevated white blood cell count, consistent with ongoing infection; and the NT‐proBNP (obtained due to shortness of breath and evidence of pleural effusion on chest X‐ray [CXR]) was markedly elevated, prompting transthoracic echocardiography (TTE). TTE demonstrated a large, irregular, independently mobile mass adherent to the pacemaker lead within the right atrium, prolapsing across the tricuspid valve into the right ventricle during diastole (≈2.3 × 1.0 cm), mild tricuspid regurgitation and normal biventricular systolic function. Transoesophageal echocardiography (TOE) confirmed a similar lead‐adherent structure (≈2.5 × 1.0 cm), supporting a diagnosis of pacemaker‐related IE in the appropriate clinical context. The patient was referred for complete device extraction at a specialist centre. This case highlights the diagnostic and management challenges of blood culture–negative endocarditis, the central role of echocardiography in the diagnosis of IE and the importance of integrating and interpreting imaging findings in the wider clinical context.
No takes yet. Share an insight, caveat, or question.
Townsend et al. (2026) conducted a case report in Blood culture-negative infective endocarditis (CIED-related) (n=1). Echocardiography (TTE and TOE) was evaluated. Echocardiography prompted by an elevated NT-proBNP revealed a large pacemaker lead-adherent mass, establishing the diagnosis of blood culture-negative infective endocarditis and guiding subsequent complete device extraction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: