Key result
Higher 24-hour pulse pressure is linked to ~39% higher all-cause mortality in PD patients.
Why the study?
Whether 24 h pulse pressure derived from ambulatory blood pressure monitoring is independently associated with all-cause and cardiovascular mortality in peritoneal dialysis patients remains unclear.
Does elevated 24 h pulse pressure derived from ambulatory blood pressure monitoring predict all-cause and cardiovascular mortality in patients undergoing peritoneal dialysis?
Cohort (n=165)
No
Does elevated 24 h pulse pressure derived from ambulatory blood pressure monitoring predict all-cause and cardiovascular mortality in patients undergoing peritoneal dialysis?
Hazard Ratio: 1.39 (95% CI 1.03–1.87)
p-value: p=0.032
Elevated 24-hour pulse pressure on ambulatory monitoring is an independent predictor of all-cause and cardiovascular mortality in peritoneal dialysis patients.
Background/Objectives: Pulse pressure (PP), an indirect hemodynamic marker reflecting the pulsatile component of blood pressure, has been linked to adverse outcomes in dialysis patients. Whether 24 h PP (24 h PP) derived from ambulatory BP monitoring (ABPM) is independently associated with all-cause and cardiovascular (CV) mortality in peritoneal dialysis (PD) patients remains unclear. Methods: This sub-cohort, nested within a single-center prospective PD database, enrolled 165 patients with baseline 24 h ABPM. The 24 h PP was analyzed continuously and in tertiles. All-cause mortality was assessed by Cox regression and CV mortality by Fine–Gray competing-risk modeling. The median follow-up was 47.4 months, counted from the date of ABPM completion. Results: During follow-up, 48 patients (29.1%) died, including 28 CV deaths (58.3% of all deaths). Per 1-SD increment in 24 h PP, the adjusted hazard ratio (HR) for all-cause mortality was 1.39 (95% confidence interval [CI] 1.03–1.87; p = 0.032), and the adjusted subdistribution hazard ratio (SHR) for CV mortality was 1.44 (95% CI 1.06–1.94; p = 0.018). The highest tertile showed elevated risks of all-cause (HR 3.47; 95% CI 1.12–10.70; p = 0.031) and CV mortality (SHR 5.11; 95% CI 1.32–19.79; p = 0.018) versus the lowest, persisting after adjustment for office PP. Conclusions: Elevated ABPM-derived 24 h PP is independently associated with increased all-cause and CV mortality in PD patients after adjustment for office PP.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) conducted a cohort in peritoneal dialysis (n=165). 24 h pulse pressure vs. Lower 24 h pulse pressure was evaluated on All-cause mortality (HR 1.39, 95% CI 1.03-1.87, p=0.032). Each 1-SD increment in 24 h pulse pressure was associated with increased risks of all-cause (HR 1.39; 95% CI 1.03–1.87) and cardiovascular mortality (SHR 1.44; 95% CI 1.06–1.94) in PD patients.