Answers are grounded in this paper and cite their sources.
Theoretical analysis reveals the voltage mechanisms driving geomagnetically induced currents in grounded power grids, indicating that surface electric fields reliably approximate line-level values.
Geomagnetically induced currents (GICs) in grounded transmission networks are usually calculated by applying the Lehtinen–Pirjola (LP) formulation to the surface electric field obtained from measurements or modeling. However, several fundamental questions remain concerning (1) the physically appropriate picture that explains the induced electric field driving GICs, (2) the incorporation of electrostatic potentials arising from inhomogeneous ground resistivity into the LP formulation, (3) the reading of a high-impedance voltmeter between earthing electrodes, and (4) the validity of using the surface electric field as a proxy for the field at transmission-line altitude. We obtained the following results. The induced electric field driving GICs can be explained in terms of both the integral and differential forms of Faraday's law. The differential form provides a clearer physical picture, in which the electric field responsible for GICs results from the superposition of a downward-propagating electromagnetic disturbance of external origin and the field reflected from the conducting Earth. We generalize the LP formulation by introducing externally imposed electrostatic potentials on the ground side of the earthing line. When a measured or modeled surface electric field already includes both induced and electrostatic components, its line integral can be used directly as the effective open-circuit voltage in the LP formulation. We confirm theoretically that a high-impedance voltmeter connected between earthing electrodes measures the electrostatic ground potential difference between them, as well as the line integral of the induced electric field along the lead-wire path. We demonstrate that, for a normally incident plane wave with periods > 1 s over a uniform ground with resistivity >10 2 Ω m, the induced electric field at typical transmission-line altitudes differs from that at the ground surface by a few percent or less. This difference is determined by the ratio of the transmission-line altitude to the skin depth for a normally incident plane wave with uniform ground resistivity. This result supports the common practice of using the surface electric field as a good proxy for the induced electric field at transmission-line altitudes.
No takes yet. Share an insight, caveat, or question.
Yusuke Ebihara (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: