This is the authors' abstract. We don't add key points for this paper.
Managing drug expiry and the usable period of finished infusions is a key component of medication safety in a pharmacy intravenous admixture service (PIVAS). We developed a pharmacy service model based on drug life cycle management (DLCM) and evaluated its preliminary effects on inventory and workflow indicators in a single-centre PIVAS. This single-centre, uncontrolled before-and-after quality-improvement study was conducted in the PIVAS of a tertiary general hospital in Chongqing, China. January 2024 served as the baseline month and February–May 2024 as the post-implementation period. The DLCM model comprised three phases: drug quality management based on a three-tiered information system integrating the hospital information system (HIS), an intelligent secondary storehouse, and a central scheduling machine; rational drug-use management including pharmacist prescription review, individualised infusion-batch decisions, and drug information management; and drug therapy management including finished-infusion beyond-use date (BUD) guidance, QR-code infusion prompts, real-time administration monitoring, and one-click medicine return. Outcomes included the near-expiry inventory rate, the proportion of near-expiry drug varieties, the configuration-to-administration interval (from configuration completion to infusion start), and clinical department satisfaction; each post-implementation month was compared with the January 2024 baseline. Compared with January 2024, the near-expiry inventory rate (by value) decreased from 4.91 to 2.05% in May 2024 (relative reduction 58.2%; Spearman ρ = − 1.0, P = 0.017), and the proportion of near-expiry varieties decreased from 6.04 to 3.04% (relative reduction 49.7%; Cochran–Armitage trend test, P = 0.012). The mean configuration-to-administration interval decreased from 206.8 min in January to 149.5 min in May 2024 (Welch’s t-test, P < 0.0001; Cohen’s d = 0.36), with significant reductions in all seven infusion batches. Overall clinical department satisfaction increased from 2.40 ± 0.74 to 4.33 ± 0.62 on a 5-point scale (paired t-test, P < 0.0001). Implementation of the DLCM-based PIVAS model was associated with improvements in selected inventory and workflow indicators and increased staff satisfaction during the four-month post-implementation period. Because of the single-centre uncontrolled design, the one-month baseline, and the absence of patient-level safety outcomes, these findings are preliminary and no causal conclusions can be drawn. Multicentre studies with longer follow-up and direct medication-safety measures are warranted.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: