Key result
Targeted pre-TAVI CTA protocol cuts radiation dose ~13% without compromising image quality.
Why the study?
The optimal pre-TAVI CTA protocol balancing image quality, radiation dose, and contrast volume has not been established.
Does an optimized pre-TAVI CTA protocol restricting ECG-gating to the heart and aortic root reduce radiation and contrast dose compared to ECG-gated thorax CTA?
RCT (n=64)
randomly assigned
Does an optimized pre-TAVI CTA protocol restricting ECG-gating to the heart and aortic root reduce radiation and contrast dose compared to ECG-gated thorax CTA?
Absolute Event Rate: 13.7% vs 15.7%
p-value: p=<0.001
An optimized pre-TAVI CTA protocol restricting ECG-gating to the heart and aortic root significantly reduces radiation and contrast dose without compromising image quality.
An optimized pre-TAVI CTA protocol may lower radiation and contrast exposure without compromising image quality; this leaves open the need for larger randomized confirmation before routine adoption.
BACKGROUND: To establish the most effective and safe pre-transcatheter aortic valve implantation (TAVI) CT angiography (CTA) protocol by comparing two approaches in terms of image quality, radiation and contrast dose. METHODS: Consecutive patients undergoing pre-procedural CTA were prospectively enrolled from January to May 2024. Patients were randomly assigned into two different acquisition protocols: group A underwent an ECG-gated CTA of the thorax followed by a non-gated helical scan of abdomen and pelvis; group B underwent an ECG-gated CTA including only the heart and aortic root, followed by a non-gated helical scan of thorax, abdomen, and pelvis. Objective image analysis was performed by evaluating vascular attenuation, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in multiple segments. Subjective image analysis was evaluated by two radiologists and radiation and contrast dose were compared between the groups. RESULTS: The final population consisted of 64 patients, 37 in group A and 27 in group B (80.6 ± 5.2 years; 49 males). Group B showed lower radiation dose compared to group A (13.7 ± 1.2 vs 15.7 ± 1.4 mSv; p < 0.001) and lower contrast medium volume (82.9 ± 10.1 vs 90.3 ± 12.0 ml; p = 0.004) while achieving no differences in terms of signal-to-noise ratio, contrast-to-noise ratio and subjective image quality (all p > 0.05). Average vascular attenuation was higher in group A compared to group B (707.1 ± 120.7 vs 633.0 ± 198.6 HU; p < 0.001); however, lumen attenuation at the aortic root was consistent across the two protocols (p = 0.077). CONCLUSIONS: Optimization of pre-TAVI CTA protocol results in lower contrast medium volume and radiation dose exposure while maintaining consistent image quality.
No takes yet. Share an insight, caveat, or question.
Tremamunno et al. (2025) conducted an RCT in pre-transcatheter aortic valve implantation (TAVI) (n=64). ECG-gated CTA of heart and aortic root followed by non-gated helical scan of thorax, abdomen, and pelvis vs. ECG-gated CTA of the thorax followed by non-gated helical scan of abdomen and pelvis was evaluated on Radiation dose (mSv) (p=<0.001). An optimized pre-TAVI CTA protocol restricting ECG-gating to the heart and aortic root reduced radiation dose (13.7 vs 15.7 mSv; p<0.001) and contrast volume without compromising image quality.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: