This study investigated indoor environmental and thermal insulation retrofit performance in wooden rental apartment housing in Sapporo. Questionnaire surveys revealed that about 30% of residents were dissatisfied with noise, coldness, and condensation. Field measurements showed that living-room temperatures were generally maintained above 20°C, while bedroom temperatures tended to be lower. Indoor CO2 concentrations suggested insufficient ventilation. Although airtightness performance improved after thermal insulation retrofits, measured Q-values in many apartments were lower than the designed Q-values. These results suggest that current performance evaluation methods may overestimate the actual thermal performance of apartments under real occupancy conditions.